Set Up an In/Out Door with Two Readers
Set up a single door with an inbound reader and an outbound reader
An in/out door uses two consecutive door ports on an access controller:
Door slot 1 (and sequentially any odd numbered port) is used for:
Door relay output
REX input(s)
DPI input
Inbound access reader, wired into the Wiegand or RS-485 reader inputs
Door port 2 (and sequentially any even numbered port**)** is used for an Outbound access reader, wired into the Wiegand or RS-485 reader inputs:

Learn more about how to wire a door to a Verkada access controller.
Set up an in/out door from Verkada Command
In/out door setup is very similar as normal door setup, with two small differences:
When you add the door to the access controller, select In/Out Door instead of Door.
When you configure the in/out door, select two consecutive door ports on the access controller.
Requirements
Ensure that you have a Verkada access controller. This access controller must have two available reader slots for the in/out door that you set up.
To set up in/out doors in Verkada Command, you must be logged in to the organization.
How it works
You can now continue to set up this door as if it was a normal door. If you apply a schedule to the door, the schedules carries over to both readers.
Changes in the door events page
The Inbound and Outbound Readers can produce events that are tagged with the inbound or outbound direction. Access attempts, such as Keycard Unlock/Keycard Denied, now appear annotated with direction they are associated with (as shown below).

There is now an added filter on the door events page that allows users to choose to filter events based on the direction (Inbound/Outbound). This filter can be used in conjunction with all the other existing filters (as shown below).